| Category |
| Keyword |
|
Add to Cart
|
Click to Buy
|
Part Number
|
Part Description
|
Most Used
|
CSR
|
Tech Courier
|
RoHS
|
| 30463A Cabinet Parts |
|
PDU
|
|
|
|
142258-001
|
AC Power Distribution Unit (PDU) power cord (Black) - 250 V ac, 16 AWG, 2.0 m (6.6 ft) long - Includes IEC-320 C14 (M) connector to IEC 320 C13 (F) connector
|
|
A
|
-N/A-
|
COMPLY_2706
|
| Accessories |
|
Controller
|
|
|
|
824019-001
|
Express bay bridge board - Non-Volatile Memory express (NVMe) interface PCIe controller board with three internal 68-pin connectors for controlling up to six NVMe drives - Requires one PCIe (Gen 3) x16 slot
|
|
B
|
-N/A-
|
COMPLY_5012
|
| Cables |
|
Cable
|
|
|
|
|
825356-001
|
Cable assembly - Power, SCSIe/2SSf-8SFF
|
|
A
|
-N/A-
|
COMPLY_2106
|
|
Cable Kit
|
|
|
|
|
784621-001
|
Mini-SAS cable assembly kit (Includes two mini-SAS cables) - For connecting the 8-bay Small Form Factor (SFF) hard drive cage to the drive controller board
|
|
A
|
-N/A-
|
COMPLY_5012
|
|
|
|
784622-001
|
Power cable kit (Includes two cables) - For connecting the small form factor 8-bay (or three 8-bay) hard drive cages, or large form factor 4-bay, or 12-bay hard drive cages to the system I/O board
|
|
A
|
-N/A-
|
COMPLY_5012
|
|
|
|
822780-001
|
Miscellaneous cable kit
|
|
A
|
-N/A-
|
COMPLY_2912
|
| Cabling Accessories/Tools |
|
Cable Kit
|
|
|
|
|
784621-001
|
Mini-SAS cable assembly kit (Includes two mini-SAS cables) - For connecting the 8-bay Small Form Factor (SFF) hard drive cage to the drive controller board
|
|
A
|
-N/A-
|
COMPLY_5012
|
|
|
|
784622-001
|
Power cable kit (Includes two cables) - For connecting the small form factor 8-bay (or three 8-bay) hard drive cages, or large form factor 4-bay, or 12-bay hard drive cages to the system I/O board
|
|
A
|
-N/A-
|
COMPLY_5012
|
|
|
|
822780-001
|
Miscellaneous cable kit
|
|
A
|
-N/A-
|
COMPLY_2912
|
| Chassis Parts |
|
Cage
|
|
|
|
777281-001
|
PCI riser cage assembly - 3-slot standard primary PCI riser board - Includes one full-length PCIe3 x16 slot, one half-length PCIe3 x16 slot, and one half-length PCIe3 x8 slot ;
|
|
A
|
-N/A-
|
COMPLY_5012
|
|
|
|
777294-001
|
Fan cage assembly - Holds six fan modules - Mounts in the bottom of the chassis between the hard drives and the system I/O board
|
|
A
|
-N/A-
|
COMPLY_2912
|
|
|
|
780971-001
|
8-bay hot-plug small form factor (SFF) hard drive cage assembly - Includes the metal cage structure and the SAS backplane board - Mounts in the front of the server
|
|
B
|
-N/A-
|
COMPLY_2706
|
|
|
|
780978-001
|
Cage assembly 6 SCSIe with PCA - For use with Gen9 servers
|
|
C
|
-N/A-
|
COMPLY_2912
|
|
Cover
|
|
|
|
775423-001
|
DL560/DL360 Gen9 blank cover kit - Contains power supply blank cover, Flexible LOM blank cover, fan slot blank, and Heat Sink blank
|
|
A
|
-N/A-
|
COMPLY_5012
|
|
|
|
777301-001
|
Blank cover kit - Contains one power supply blank cover, two 8-bay small form factor (SFF) hard drive cage blank covers, one secondary PCI blank cover, two fan slot blanks, and one Smart Array Controller blank
|
|
A
|
-N/A-
|
COMPLY_5012
|
|
Hardware
|
|
|
|
777295-001
|
Rack ear kit (standard) - Includes the left and right rack mount ears for servers with front small form factor (SFF) hard drive bays
|
|
A
|
-N/A-
|
COMPLY_5012
|
|
|
|
783227-001
|
Right rack ear (standard) - Includes the right rack mount ear with the HP logo and the 'ProLiant DL388 Gen9' nameplate - For servers with front small form factor (SFF) hard drive bays
|
|
A
|
-N/A-
|
COMPLY_5012
|
| Chassis/Hardware |
|
Airflow Guide
|
|
|
|
777302-001
|
Airflow baffle - Plastic baffle that mounts behind the fan cage on top of the processor heat sinks
|
|
A
|
-N/A-
|
COMPLY_2912
|
|
Cover
|
|
|
|
775423-001
|
DL560/DL360 Gen9 blank cover kit - Contains power supply blank cover, Flexible LOM blank cover, fan slot blank, and Heat Sink blank
|
|
A
|
-N/A-
|
COMPLY_5012
|
|
|
|
777301-001
|
Blank cover kit - Contains one power supply blank cover, two 8-bay small form factor (SFF) hard drive cage blank covers, one secondary PCI blank cover, two fan slot blanks, and one Smart Array Controller blank
|
|
A
|
-N/A-
|
COMPLY_5012
|
|
Hardware
|
|
|
|
777295-001
|
Rack ear kit (standard) - Includes the left and right rack mount ears for servers with front small form factor (SFF) hard drive bays
|
|
A
|
-N/A-
|
COMPLY_5012
|
|
|
|
783227-001
|
Right rack ear (standard) - Includes the right rack mount ear with the HP logo and the 'ProLiant DL388 Gen9' nameplate - For servers with front small form factor (SFF) hard drive bays
|
|
A
|
-N/A-
|
COMPLY_5012
|
| Controller Module Parts |
|
Controller
|
|
|
|
824019-001
|
Express bay bridge board - Non-Volatile Memory express (NVMe) interface PCIe controller board with three internal 68-pin connectors for controlling up to six NVMe drives - Requires one PCIe (Gen 3) x16 slot
|
|
B
|
-N/A-
|
COMPLY_5012
|
| Drive Parts |
|
Drive
|
|
|
|
777279-001
|
SAS/SATA backplane board - Mounts on the rear of the 8-bay small form factor (SFF) hard drive cage - Performance is up to 12 Gb/s transfer speed
|
|
A
|
-N/A-
|
COMPLY_5012
|
| Electronic Accessories |
|
Cable
|
|
|
|
|
825356-001
|
Cable assembly - Power, SCSIe/2SSf-8SFF
|
|
A
|
-N/A-
|
COMPLY_2106
|
| Electronic Parts |
|
Cage
|
|
|
|
777281-001
|
PCI riser cage assembly - 3-slot standard primary PCI riser board - Includes one full-length PCIe3 x16 slot, one half-length PCIe3 x16 slot, and one half-length PCIe3 x8 slot ;
|
|
A
|
-N/A-
|
COMPLY_5012
|
|
|
|
777294-001
|
Fan cage assembly - Holds six fan modules - Mounts in the bottom of the chassis between the hard drives and the system I/O board
|
|
A
|
-N/A-
|
COMPLY_2912
|
|
|
|
780971-001
|
8-bay hot-plug small form factor (SFF) hard drive cage assembly - Includes the metal cage structure and the SAS backplane board - Mounts in the front of the server
|
|
B
|
-N/A-
|
COMPLY_2706
|
|
|
|
780978-001
|
Cage assembly 6 SCSIe with PCA - For use with Gen9 servers
|
|
C
|
-N/A-
|
COMPLY_2912
|
|
Drive
|
|
|
|
777279-001
|
SAS/SATA backplane board - Mounts on the rear of the 8-bay small form factor (SFF) hard drive cage - Performance is up to 12 Gb/s transfer speed
|
|
A
|
-N/A-
|
COMPLY_5012
|
|
Module
|
|
|
|
777289-001
|
Standard cabled power switch module assembly (no internal system insight display) - Includes the power switch, UID switch, and status LEDs - For use with servers configured with small form factor (SFF) drive bays
|
|
A
|
-N/A-
|
COMPLY_2912
|
|
PC Board
|
|
|
|
775400-001
|
System I/O board (motherboard) assembly - For Intel Xeon E5-2600 series v3 (Haswell) processors ONLY - Includes subpan, thermal grease, alcohol pad, and instruction card - Processors must be the same spare part number
;
|
|
B
|
-N/A-
|
COMPLY_5012
|
|
|
|
843307-001
|
System I/O board (motherboard) assembly - For Intel Xeon E5-2600 series v3 (Haswell) and v4 (Broadwell) processors - Includes the system I/O board, alcohol pad, thermal grease, and installation instruction card - Processors must be same spare part number ;
|
|
B
|
-N/A-
|
COMPLY_5012
|
|
|
|
|
878936-001
|
System I/O board (motherboard) assembly - For Intel Xeon E5-2600 series v4 (Broadwell) processors - Includes the system I/O board, alcohol pad, thermal grease with subpan
|
|
B
|
-N/A-
|
COMPLY_2912
|
| Fan Module Parts |
|
Fan
|
|
|
|
|
777285-001
|
SPS-Fan Module (STD) DL38x Gen9 ;
|
|
A
|
-N/A-
|
COMPLY_2912
|
|
|
|
777286-001
|
High performance fan module - For use on servers configured with 12 large form factor drives, 24 small form factor drives, certain graphics cards, and/or ASHRAE operating environments (Six used) ;
|
|
A
|
-N/A-
|
COMPLY_2706
|
| Miscellaneous Parts |
|
Airflow Guide
|
|
|
|
777302-001
|
Airflow baffle - Plastic baffle that mounts behind the fan cage on top of the processor heat sinks
|
|
A
|
-N/A-
|
COMPLY_2912
|
| Power Cords |
|
PDU
|
|
|
|
142258-001
|
AC Power Distribution Unit (PDU) power cord (Black) - 250 V ac, 16 AWG, 2.0 m (6.6 ft) long - Includes IEC-320 C14 (M) connector to IEC 320 C13 (F) connector
|
|
A
|
-N/A-
|
COMPLY_2706
|
Power Cord
|
|
|
|
|
142263-003
|
Power cord OPT-905 - 3-wire, 3.0 m (9.8 ft) long
|
|
N
|
-N/A-
|
COMPLY_2706
|
|
|
|
491683-AA1
|
AC power 3-wire, 1.83 m (6 ft) long cord black
|
|
A
|
-N/A-
|
COMPLY_2706
|
|
|
|
|
538266-001
|
Power cord (black) - Three conductor, 1.82 m (6 ft) long - Has straight (F) C13 receptacle (For 100 V in Japan)
|
|
A
|
-N/A-
|
COMPLY_2706
|
| Router Parts |
|
Module
|
|
|
|
777289-001
|
Standard cabled power switch module assembly (no internal system insight display) - Includes the power switch, UID switch, and status LEDs - For use with servers configured with small form factor (SFF) drive bays
|
|
A
|
-N/A-
|
COMPLY_2912
|
| System Electronics Parts |
|
Fan
|
|
|
|
|
777285-001
|
SPS-Fan Module (STD) DL38x Gen9 ;
|
|
A
|
-N/A-
|
COMPLY_2912
|
|
|
|
777286-001
|
High performance fan module - For use on servers configured with 12 large form factor drives, 24 small form factor drives, certain graphics cards, and/or ASHRAE operating environments (Six used) ;
|
|
A
|
-N/A-
|
COMPLY_2706
|