A camera icon in this column next to a part number indicates that a diagram or photograph is available showing that part. Click on the icon to retrieve the diagram or photo. Add to Cart Click to Buy Part Number Part Description Most Used CSR Tech Courier  RoHS
30463A Cabinet Parts
PDU
142258-001 AC Power Distribution Unit (PDU) power cord (Black) - 250 V ac, 16 AWG, 2.0 m (6.6 ft) long - Includes IEC-320 C14 (M) connector to IEC 320 C13 (F) connector A -N/A- COMPLY_2706
142258-002 AC Power Distribution Unit (PDU) power cord (Black) - 250 V ac, 16 AWG, 2.5 m (8.2 ft) long - Includes IEC-320 C14 (M) connector to IEC 320 C13 (F) connector A -N/A- COMPLY_5012
416151-B21 Power Distribution Unit (PDU) power cord -N/A- -N/A- COMPLY_2706
Accessories
Bezel
662529-001 2U security bezel assembly - Locking cover that covers the front of the server to protect from removing the hard drives or accessing the optical drive A -N/A- COMPLY_5012
670945-001 Left bezel ear assembly A -N/A- COMPLY_1405
Controller
749797-001 Smart Array P440 PCIe3 x8 SAS controller - Internal x8 mini-SAS double-wide port, 4GB of Flashed Back Write Cache (FBWC) memory, 12 Gb/s transfer rate SAS, 6 Gb/s transfer rate SATA - Does not include battery, FBWC cannot be ordered separately B -N/A- COMPLY_5012
761880-001 Smart Array P840 PCIe3 x8 SAS controller - Two internal x8 mini-SAS double-wide ports and 4GB of flashed back write cache (FBWC) memory - For up to 12 Gb/sec transfer rate SAS and 6 Gb/sec SATA - Does not include battery, FBWC cannot be ordered separately B -N/A- COMPLY_5012
Adapter
Adapter
669279-001 Ethernet 10Gb 2-port 560SFP+ adapter - Has two 10Gbe SFP+ ports and 256MB integrated memory - Provides up to 40Gb/sec bi-directional per adapter - Requires one x8 PCI (Gen 2) Express slot (backward compatible with x4 PCI Express) ; B -N/A- COMPLY_2912
669281-001 Ethernet 10Gb 2-port 560FLR-SFP+ adapter, FlexibleLOM form-factor - Has two 10Gbe SFP+ ports and 128MB integrated memory - Provide up to 40Gb bi-directional per adapter - Requires one x8 PCI (Gen 2) Express slot B -N/A- COMPLY_2912
701525-001 Ethernet 10Gb 2-port 561FLR-T adapter, FlexibleLOM form factor - Has two 10Gbps RJ45 ports featuring the 10Gb Intel X540 Controller - Requires one x8 PCI (Gen 2) FlexibleLOM slot - Requires CAT6 UTP or better twisted-pair B -N/A- COMPLY_2912
717708-002 Ethernet 10Gb 2-port 561T adapter - Has two 10G BASE-T RJ45 ports and has Intel X540 processor - Requires one x8 (Gen2) PCI Express slot - Requires CAT6A UTP or better twisted-pair B -N/A- COMPLY_2912
789897-001 Ethernet 1Gb 4-port 331FLR adapter, FlexibleLOM form-factor - Has four 10/100/1000BASE-T RJ45 ports and 276MB integrated memory - Requires one x4 PCI (Gen 2) FlexibleLOM slot (mechanically compatible with x8 and x16 PCI FlexibleLOM slots) N -N/A- COMPLY_5012
Cables
Cable
780418-001 8-bay small form factor (SFF) power cable - Connects between the front 8-bay backplane board and the system I/O board A -N/A- COMPLY_5012
784624-001 Power cable kit - Includes a cable for the rear 2-bay small form factor (SFF) drive cage, "Y" cable for the rear 2-bay plus the front three 8-bays small form factor (SFF) hard drive cages, and a cable for the 4-bay large form factor (LFF) hard drive cage A -N/A- COMPLY_5012
784626-001 Mini-SAS cable - Connects between the rear 3-bay large form factor (LFF) or 2-bay small form factor (SFF) drive cages and the SAS controller board A -N/A- COMPLY_5012
792836-001 PCI to controller power cable (short) - straight 3-pin (F) to straight 3-pin (F), 215 mm (8.5 inches) long A -N/A- COMPLY_5012
792837-001 PCI to controller power cable (long) - straight 3-pin (F) to straight 3-pin (F), 400 mm (15.7 inches) long A -N/A- COMPLY_2912
805122-001 Universal media bay power cable - Connects between the optional two bay small form factor (SFF) drive cage and the drive backplane power connector on the system I/O board A -N/A- COMPLY_5012
Cable Kit
784621-001 Mini-SAS cable assembly kit (Includes two mini-SAS cables) - For connecting the 8-bay Small Form Factor (SFF) hard drive cage to the drive controller board A -N/A- COMPLY_5012
784622-001 Power cable kit (Includes two cables) - For connecting the small form factor 8-bay (or three 8-bay) hard drive cages, or large form factor 4-bay, or 12-bay hard drive cages to the system I/O board A -N/A- COMPLY_5012
784625-001 Mini-SAS cable kit - For the front or rear 2-bay small form factor (SFF) hard drive cage - Includes a mini-SAS to mini-SAS cable and a mini-SAS to SATA cable A -N/A- COMPLY_5012
784629-001 Mini-SAS cable kit (Includes six cables) - For connecting between the 8-bay and 2-bay small form factor (SFF) hard drive cages and the H240 host bus adapter or the P440ar controller board A -N/A- COMPLY_5012
Cabling Accessories/Tools
Cable Kit
784621-001 Mini-SAS cable assembly kit (Includes two mini-SAS cables) - For connecting the 8-bay Small Form Factor (SFF) hard drive cage to the drive controller board A -N/A- COMPLY_5012
784622-001 Power cable kit (Includes two cables) - For connecting the small form factor 8-bay (or three 8-bay) hard drive cages, or large form factor 4-bay, or 12-bay hard drive cages to the system I/O board A -N/A- COMPLY_5012
784625-001 Mini-SAS cable kit - For the front or rear 2-bay small form factor (SFF) hard drive cage - Includes a mini-SAS to mini-SAS cable and a mini-SAS to SATA cable A -N/A- COMPLY_5012
784629-001 Mini-SAS cable kit (Includes six cables) - For connecting between the 8-bay and 2-bay small form factor (SFF) hard drive cages and the H240 host bus adapter or the P440ar controller board A -N/A- COMPLY_5012
Chassis Parts
Arm
744116-001 Cable management arm kit - Guides the power and interface cables to prevent binding when the server is slid in and out of the rack - Mounts to the rear of the rack A -N/A- COMPLY_5012
Cage
777281-001 PCI riser cage assembly - 3-slot standard primary PCI riser board - Includes one full-length PCIe3 x16 slot, one half-length PCIe3 x16 slot, and one half-length PCIe3 x8 slot ; A -N/A- COMPLY_5012
777283-001 PCI-E riser 2 assembly - 3 slot 2-PCIe3 x16 x8 ; A -N/A- COMPLY_5012
777294-001 Fan cage assembly - Holds six fan modules - Mounts in the bottom of the chassis between the hard drives and the system I/O board A -N/A- COMPLY_2912
780971-001 8-bay hot-plug small form factor (SFF) hard drive cage assembly - Includes the metal cage structure and the SAS backplane board - Mounts in the front of the server B -N/A- COMPLY_2706
814059-001 Flex bay assembly (cage) - Includes the flex bay cage with integrated optical drive bay (with blank cover), two small form factor (SFF) cage assembly with SAS backplane board, and front cable assembly that includes a VGA port and two USB ports B -N/A- COMPLY_2912
Cover
667276-001 Hard drive blank (Cover) - To fill empty Small Form Factor (SFF) drive bays - Gen8 A -N/A- COMPLY_5012
775423-001 DL560/DL360 Gen9 blank cover kit - Contains power supply blank cover, Flexible LOM blank cover, fan slot blank, and Heat Sink blank A -N/A- COMPLY_5012
777301-001 Blank cover kit - Contains one power supply blank cover, two 8-bay small form factor (SFF) hard drive cage blank covers, one secondary PCI blank cover, two fan slot blanks, and one Smart Array Controller blank A -N/A- COMPLY_5012
Hardware
385973-001 Mini stabilizer (10000 G2) - 0.6mm (23.6in) - Includes side foot, M8 flat washers, and bolts A -N/A- COMPLY_1906
777295-001 Rack ear kit (standard) - Includes the left and right rack mount ears for servers with front small form factor (SFF) hard drive bays A -N/A- COMPLY_5012
783227-001 Right rack ear (standard) - Includes the right rack mount ear with the HP logo and the 'ProLiant DL388 Gen9' nameplate - For servers with front small form factor (SFF) hard drive bays A -N/A- COMPLY_5012
Heat Sink
777290-001 Standard efficiency heatsink assembly - For use with processors less than or equal to 105W A -N/A- COMPLY_5012
Chassis/Hardware
Airflow Guide
777302-001 Airflow baffle - Plastic baffle that mounts behind the fan cage on top of the processor heat sinks A -N/A- COMPLY_2912
Bezel
662529-001 2U security bezel assembly - Locking cover that covers the front of the server to protect from removing the hard drives or accessing the optical drive A -N/A- COMPLY_5012
670945-001 Left bezel ear assembly A -N/A- COMPLY_1405
Bracket
111567-001 Hard drive bay bracket 5.25-inch N -N/A- -N/A-
667263-001 Support bracket with card guides - Supports the rear of the PCIe cards when installed on the system I/O board - Includes left and right support brackets A -N/A- COMPLY_5012
Cover
667276-001 Hard drive blank (Cover) - To fill empty Small Form Factor (SFF) drive bays - Gen8 A -N/A- COMPLY_5012
775423-001 DL560/DL360 Gen9 blank cover kit - Contains power supply blank cover, Flexible LOM blank cover, fan slot blank, and Heat Sink blank A -N/A- COMPLY_5012
777301-001 Blank cover kit - Contains one power supply blank cover, two 8-bay small form factor (SFF) hard drive cage blank covers, one secondary PCI blank cover, two fan slot blanks, and one Smart Array Controller blank A -N/A- COMPLY_5012
Hardware
385973-001 Mini stabilizer (10000 G2) - 0.6mm (23.6in) - Includes side foot, M8 flat washers, and bolts A -N/A- COMPLY_1906
777295-001 Rack ear kit (standard) - Includes the left and right rack mount ears for servers with front small form factor (SFF) hard drive bays A -N/A- COMPLY_5012
783227-001 Right rack ear (standard) - Includes the right rack mount ear with the HP logo and the 'ProLiant DL388 Gen9' nameplate - For servers with front small form factor (SFF) hard drive bays A -N/A- COMPLY_5012
Hardware Kit
809955-001 Miscellaneous blank kit for Apollo 4200 - Includes air blocker for PCIe expansion slots 5-7, air blocker for front 2-drive cage backplane, chassis retention bracket, fan blank, LFF and SFF drive blank, cable management holder, and FlexibleLOM blank A -N/A- COMPLY_5012
Controller Module Parts
Controller
749797-001 Smart Array P440 PCIe3 x8 SAS controller - Internal x8 mini-SAS double-wide port, 4GB of Flashed Back Write Cache (FBWC) memory, 12 Gb/s transfer rate SAS, 6 Gb/s transfer rate SATA - Does not include battery, FBWC cannot be ordered separately B -N/A- COMPLY_5012
761880-001 Smart Array P840 PCIe3 x8 SAS controller - Two internal x8 mini-SAS double-wide ports and 4GB of flashed back write cache (FBWC) memory - For up to 12 Gb/sec transfer rate SAS and 6 Gb/sec SATA - Does not include battery, FBWC cannot be ordered separately B -N/A- COMPLY_5012
DIMM Memory Module Parts
Memory (DIMM)
774172-001 16GBPC4-2133P-R, registered synchronous dynamic random access memory (SDRAM),dual data rate(DDR4) mode, dual in-line memory module (DIMM), organized as 2Gx72 ; A -N/A- COMPLY_5012
774175-001 32GB, 2133MHz, PC4-2133P-R, DDR4, dual-rank x4, 1.20V, CAS-15-15-15, registered dual in-line memory module (RDIMM) -Supports StoreOnce 6600 Cloud Bank Storage configurations - NOTE: DIMM is not used exclusively in StoreOnce products A -N/A- COMPLY_5012
774176-001 64GB, 2133MHz, PC4-2133P-L, DDR4, quad-rank x4, 1.20V, CAS-15-15-15, load reduced dual in-line memory module (LRDIMM) A -N/A- COMPLY_5012
819412-001 HPE SmartMemory 32GB, 2400MHz, PC4-2400T-R, DDR4, dual-rank x4, 1.20V, CAS-17-17-17, registered dual in-line memory module (RDIMM) A -N/A- COMPLY_5012
819413-001 64GB LRDIMM - Quad Rank x4 DDR4-2400 CAS-17-17-17 Load Reduced Memory Kit (For use in E5-2600 v4 series Processors) A -N/A- COMPLY_5012
846740-001 HPE SmartMemory 16GB, 2400MHz, PC4-2400T-R, DDR4, dual-rank x4, 1.20V, CAS-17-17-17, Registered Dual in-Line Memory Module (RDIMM) A -N/A- COMPLY_5012
Drive Parts
Drive
777279-001 SAS/SATA backplane board - Mounts on the rear of the 8-bay small form factor (SFF) hard drive cage - Performance is up to 12 Gb/s transfer speed A -N/A- COMPLY_5012
781577-001 600GB hot-plug SAS hard disk drive - 12Gb/sec transfer rate, 10,000 RPM, 2.5-inch small form factor (SFF), SmartDrive Carrier (SC) - For use with Gen8/Gen9 or newer ; A -N/A- COMPLY_5012
781578-001 1.2TB hot-plug SAS hard disk drive - 12Gb/sec transfer rate, 10,000 RPM, 2.5-inch small form factor (SFF), SmartDrive Carrier (SC) - For use with Gen8/Gen9 or newer A -N/A- COMPLY_5012
785411-001 900GB hot-plug SAS hard disk drive - 12Gb/sec transfer rate, 10,000 RPM, 2.5-inch small form factor (SFF), Enterprise, SmartDrive Carrier (SC) A -N/A- COMPLY_5012
805363-001 240GB hot-plug Solid State Drive (SSD) - SATA interface, Read Intensive-2 (RI), 6Gb/sec transfer rate, 2.5-inch small form factor (SFF), Smart Carrier (SC), enterprise drive, value endurance (VE), Power Loss Protection (PLP) A -N/A- COMPLY_5012
805373-001 240GB hot-plug Solid State Drive (SSD) - SATA interface, Read Intensive-2 (RI), 6Gb/sec transfer rate, 3.5-inch large form factor (LFF), Smart Carrier Converter (SCC), enterprise drive, value endurance (VE), Power Loss Protection (PLP) A -N/A- COMPLY_5012
805381-001 800GB hot-plug G1 Solid State Drive (SSD) - SATA interface, Mixed Use-2 (MU), 6Gb/sec transfer rate, 2.5-inch small form factor (SFF), Smart Carrier (SC), Power Loss Protection (PLP) A -N/A- COMPLY_5012
805382-001 800GB hot-plug G1 Solid State Drive (SSD) - SATA interface, Mixed Use-2 (MU), 6Gb/sec transfer rate, 3.5-inch large form factor (LFF), Value Endurance (VE), Enterprise Value, Smart Carrier Converter (SCC), Power Loss Protection (PLP) A -N/A- COMPLY_5012
805387-001 400GB hot-plug Solid State Drive (SSD) - SATA interface, Write Intensive-2 (WI), 6Gb/sec transfer rate, 2.5-inch small form factor (SFF), Smart Carrier (SC), Power Loss Protection (PLP) - For use with Gen8 servers and beyond A -N/A- COMPLY_5012
805388-001 400GB hot-plug Solid State Drive (SSD) - SATA interface, Write Intensive-2 (WI), 6Gb/sec transfer rate, 3.5-inch large form factor (LFF), Smart Carrier Converter (SCC), Power Loss Protection (PLP) - For use with Gen8 servers and beyond A -N/A- COMPLY_5012
805389-001 800GB hot-plug Solid State Drive (SSD) - SATA interface, Write Intensive-2 (WI), 6Gb/sec transfer rate, 2.5-inch small form factor (SFF), Smart Carrier (SC), Power Loss Protection (PLP) - For use with Gen8 servers and beyond A -N/A- COMPLY_5012
805390-001 800GB hot-plug Solid State Drive (SSD) - SATA interface, Write Intensive-2 (WI), 6Gb/sec transfer rate, 3.5-inch large form factor (LFF), Smart Carrier Converter (SCC), Power Loss Protection (PLP) - For use with Gen8 servers and beyond A -N/A- COMPLY_5012
817106-001 480GB hot-plug Solid State Drive (SSD) - SATA interface, Mixed Use-3 (MU), 6Gb/sec transfer rate, 2.5-inch small form factor (SFF), smart carrier (SC), supports power loss protection (PLP) - For use with Gen8 servers and beyond A -N/A- COMPLY_5012
817108-001 480GB hot-plug Solid State Drive (SSD) - SATA interface, Mixed Use-3 (MU), 6Gb/sec transfer rate, 3.5-inch large form factor (LFF), smart LFF to SFF tray (SCC), supports power loss protection (PLP)- For use with Gen8 servers and beyond A -N/A- COMPLY_5012
817116-001 1.92TB hot-plug Solid State Drive (SSD) - SATA interface, Mixed Use-3 (MU), 6Gb/sec transfer rate, 2.5-inch small form factor (SFF), smart carrier (SC), supports power loss protection (PLP) - For use with Gen8 servers and beyond A -N/A- COMPLY_5012
Drives
Drive
781577-001 600GB hot-plug SAS hard disk drive - 12Gb/sec transfer rate, 10,000 RPM, 2.5-inch small form factor (SFF), SmartDrive Carrier (SC) - For use with Gen8/Gen9 or newer ; A -N/A- COMPLY_5012
781578-001 1.2TB hot-plug SAS hard disk drive - 12Gb/sec transfer rate, 10,000 RPM, 2.5-inch small form factor (SFF), SmartDrive Carrier (SC) - For use with Gen8/Gen9 or newer A -N/A- COMPLY_5012
785411-001 900GB hot-plug SAS hard disk drive - 12Gb/sec transfer rate, 10,000 RPM, 2.5-inch small form factor (SFF), Enterprise, SmartDrive Carrier (SC) A -N/A- COMPLY_5012
805363-001 240GB hot-plug Solid State Drive (SSD) - SATA interface, Read Intensive-2 (RI), 6Gb/sec transfer rate, 2.5-inch small form factor (SFF), Smart Carrier (SC), enterprise drive, value endurance (VE), Power Loss Protection (PLP) A -N/A- COMPLY_5012
805373-001 240GB hot-plug Solid State Drive (SSD) - SATA interface, Read Intensive-2 (RI), 6Gb/sec transfer rate, 3.5-inch large form factor (LFF), Smart Carrier Converter (SCC), enterprise drive, value endurance (VE), Power Loss Protection (PLP) A -N/A- COMPLY_5012
805381-001 800GB hot-plug G1 Solid State Drive (SSD) - SATA interface, Mixed Use-2 (MU), 6Gb/sec transfer rate, 2.5-inch small form factor (SFF), Smart Carrier (SC), Power Loss Protection (PLP) A -N/A- COMPLY_5012
805382-001 800GB hot-plug G1 Solid State Drive (SSD) - SATA interface, Mixed Use-2 (MU), 6Gb/sec transfer rate, 3.5-inch large form factor (LFF), Value Endurance (VE), Enterprise Value, Smart Carrier Converter (SCC), Power Loss Protection (PLP) A -N/A- COMPLY_5012
805387-001 400GB hot-plug Solid State Drive (SSD) - SATA interface, Write Intensive-2 (WI), 6Gb/sec transfer rate, 2.5-inch small form factor (SFF), Smart Carrier (SC), Power Loss Protection (PLP) - For use with Gen8 servers and beyond A -N/A- COMPLY_5012
805388-001 400GB hot-plug Solid State Drive (SSD) - SATA interface, Write Intensive-2 (WI), 6Gb/sec transfer rate, 3.5-inch large form factor (LFF), Smart Carrier Converter (SCC), Power Loss Protection (PLP) - For use with Gen8 servers and beyond A -N/A- COMPLY_5012
805389-001 800GB hot-plug Solid State Drive (SSD) - SATA interface, Write Intensive-2 (WI), 6Gb/sec transfer rate, 2.5-inch small form factor (SFF), Smart Carrier (SC), Power Loss Protection (PLP) - For use with Gen8 servers and beyond A -N/A- COMPLY_5012
805390-001 800GB hot-plug Solid State Drive (SSD) - SATA interface, Write Intensive-2 (WI), 6Gb/sec transfer rate, 3.5-inch large form factor (LFF), Smart Carrier Converter (SCC), Power Loss Protection (PLP) - For use with Gen8 servers and beyond A -N/A- COMPLY_5012
817106-001 480GB hot-plug Solid State Drive (SSD) - SATA interface, Mixed Use-3 (MU), 6Gb/sec transfer rate, 2.5-inch small form factor (SFF), smart carrier (SC), supports power loss protection (PLP) - For use with Gen8 servers and beyond A -N/A- COMPLY_5012
817108-001 480GB hot-plug Solid State Drive (SSD) - SATA interface, Mixed Use-3 (MU), 6Gb/sec transfer rate, 3.5-inch large form factor (LFF), smart LFF to SFF tray (SCC), supports power loss protection (PLP)- For use with Gen8 servers and beyond A -N/A- COMPLY_5012
817116-001 1.92TB hot-plug Solid State Drive (SSD) - SATA interface, Mixed Use-3 (MU), 6Gb/sec transfer rate, 2.5-inch small form factor (SFF), smart carrier (SC), supports power loss protection (PLP) - For use with Gen8 servers and beyond A -N/A- COMPLY_5012
Electronic Accessories
Cable
780418-001 8-bay small form factor (SFF) power cable - Connects between the front 8-bay backplane board and the system I/O board A -N/A- COMPLY_5012
784624-001 Power cable kit - Includes a cable for the rear 2-bay small form factor (SFF) drive cage, "Y" cable for the rear 2-bay plus the front three 8-bays small form factor (SFF) hard drive cages, and a cable for the 4-bay large form factor (LFF) hard drive cage A -N/A- COMPLY_5012
784626-001 Mini-SAS cable - Connects between the rear 3-bay large form factor (LFF) or 2-bay small form factor (SFF) drive cages and the SAS controller board A -N/A- COMPLY_5012
792836-001 PCI to controller power cable (short) - straight 3-pin (F) to straight 3-pin (F), 215 mm (8.5 inches) long A -N/A- COMPLY_5012
792837-001 PCI to controller power cable (long) - straight 3-pin (F) to straight 3-pin (F), 400 mm (15.7 inches) long A -N/A- COMPLY_2912
805122-001 Universal media bay power cable - Connects between the optional two bay small form factor (SFF) drive cage and the drive backplane power connector on the system I/O board A -N/A- COMPLY_5012
Electronic Parts
Cage
777281-001 PCI riser cage assembly - 3-slot standard primary PCI riser board - Includes one full-length PCIe3 x16 slot, one half-length PCIe3 x16 slot, and one half-length PCIe3 x8 slot ; A -N/A- COMPLY_5012
777283-001 PCI-E riser 2 assembly - 3 slot 2-PCIe3 x16 x8 ; A -N/A- COMPLY_5012
777294-001 Fan cage assembly - Holds six fan modules - Mounts in the bottom of the chassis between the hard drives and the system I/O board A -N/A- COMPLY_2912
780971-001 8-bay hot-plug small form factor (SFF) hard drive cage assembly - Includes the metal cage structure and the SAS backplane board - Mounts in the front of the server B -N/A- COMPLY_2706
814059-001 Flex bay assembly (cage) - Includes the flex bay cage with integrated optical drive bay (with blank cover), two small form factor (SFF) cage assembly with SAS backplane board, and front cable assembly that includes a VGA port and two USB ports B -N/A- COMPLY_2912
Drive
777279-001 SAS/SATA backplane board - Mounts on the rear of the 8-bay small form factor (SFF) hard drive cage - Performance is up to 12 Gb/s transfer speed A -N/A- COMPLY_5012
Module
777288-001 Optional system insight display (SID) /power switch module assembly - Includes the SID assembly, power switch, UID switch, status LEDs, and USB connector - For use with servers configured with small form factor (SFF) drive bays A -N/A- COMPLY_2706
777289-001 Standard cabled power switch module assembly (no internal system insight display) - Includes the power switch, UID switch, and status LEDs - For use with servers configured with small form factor (SFF) drive bays A -N/A- COMPLY_2912
PC Board
843307-001 System I/O board (motherboard) assembly - For Intel Xeon E5-2600 series v3 (Haswell) and v4 (Broadwell) processors - Includes the system I/O board, alcohol pad, thermal grease, and installation instruction card - Processors must be same spare part number ; B -N/A- COMPLY_5012
PC Board (Graphics)
788358-001 NVIDIA GRID K1 Graphics Accelerator board - Requires two PCIe3 x16 slot - Has four GK107 GPUs, 16GB GDDR5 total memory (4GB per GPU), 768 CUDA (Compute Unified Device Architecture) cores, and 6-pin aux power connector C -N/A- COMPLY_1906
820178-001 NVIDIA Tesla M60 Reverse Air Flow Dual GPU PCIe graphics accelerator B -N/A- COMPLY_2912
Power Supply
754377-001 500W Flex Slot Platinum hot-plug power supply - Installs in computer chassis as primary or redundant supply (94% efficiency) - Requires 100-240VAC at 50/60Hz - Multiple power supplies used in the sever must be the same model number ; A -N/A- COMPLY_2706
754378-001 800W Flex Slot Titanium hot-plug power supply - Installs in computer chassis as primary or redundant supply (96% efficiency) - Requires 200-240VAC at 50/60Hz - Multiple power supplies used in the sever must be the same model number A -N/A- COMPLY_2706
754379-001 800W Flex Slot Universal hot-plug power supply - Installs in computer chassis as primary or redundant supply (94% efficiency) - Requires 200-277VAC at 50/60Hz or 380VDC - Multiple power supplies used in the sever must be the same model number A -N/A- COMPLY_1606
754381-001 800 Watt Flex Slot Platinum hot-plug power supply - Installs in computer chassis as primary or redundant supply (94% efficiency) - Requires 100 - 240 V ac at 50/60 Hz - Multiple power supplies used in the sever must be the same model number ; A -N/A- COMPLY_2706
754382-001 800W Flex Slot hot-plug DC power supply - Installs in computer chassis as primary or redundant supply (92% efficiency) - Requires -48 VDC nominal input voltage - Multiple power supplies used in the sever must be the same model number ; A -N/A- COMPLY_2912
754383-001 1400W Flex Slot Platinum Plus hot-plug power supply - Installs in computer chassis as primary or redundant supply (94% efficiency) - Requires 200-240VAC at 50/60Hz - Multiple power supplies used in the sever must be the same model number A -N/A- COMPLY_2706
Electronics/Power Supply
PC Board (Graphics)
788358-001 NVIDIA GRID K1 Graphics Accelerator board - Requires two PCIe3 x16 slot - Has four GK107 GPUs, 16GB GDDR5 total memory (4GB per GPU), 768 CUDA (Compute Unified Device Architecture) cores, and 6-pin aux power connector C -N/A- COMPLY_1906
820178-001 NVIDIA Tesla M60 Reverse Air Flow Dual GPU PCIe graphics accelerator B -N/A- COMPLY_2912
External Parts/Hardware
Hardware Kit
809955-001 Miscellaneous blank kit for Apollo 4200 - Includes air blocker for PCIe expansion slots 5-7, air blocker for front 2-drive cage backplane, chassis retention bracket, fan blank, LFF and SFF drive blank, cable management holder, and FlexibleLOM blank A -N/A- COMPLY_5012
Fan Module Parts
Fan
777285-001 SPS-Fan Module (STD) DL38x Gen9 ; A -N/A- COMPLY_2912
777286-001 High performance fan module - For use on servers configured with 12 large form factor drives, 24 small form factor drives, certain graphics cards, and/or ASHRAE operating environments (Six used) ; A -N/A- COMPLY_2706
KVM switch
Switch
410530-001 Server switch 2X1X16, IP console, USB/Virtual Media (VM) A -N/A- COMPLY_2706
Memory
Memory (DIMM)
774172-001 16GBPC4-2133P-R, registered synchronous dynamic random access memory (SDRAM),dual data rate(DDR4) mode, dual in-line memory module (DIMM), organized as 2Gx72 ; A -N/A- COMPLY_5012
774175-001 32GB, 2133MHz, PC4-2133P-R, DDR4, dual-rank x4, 1.20V, CAS-15-15-15, registered dual in-line memory module (RDIMM) -Supports StoreOnce 6600 Cloud Bank Storage configurations - NOTE: DIMM is not used exclusively in StoreOnce products A -N/A- COMPLY_5012
774176-001 64GB, 2133MHz, PC4-2133P-L, DDR4, quad-rank x4, 1.20V, CAS-15-15-15, load reduced dual in-line memory module (LRDIMM) A -N/A- COMPLY_5012
819412-001 HPE SmartMemory 32GB, 2400MHz, PC4-2400T-R, DDR4, dual-rank x4, 1.20V, CAS-17-17-17, registered dual in-line memory module (RDIMM) A -N/A- COMPLY_5012
819413-001 64GB LRDIMM - Quad Rank x4 DDR4-2400 CAS-17-17-17 Load Reduced Memory Kit (For use in E5-2600 v4 series Processors) A -N/A- COMPLY_5012
846740-001 HPE SmartMemory 16GB, 2400MHz, PC4-2400T-R, DDR4, dual-rank x4, 1.20V, CAS-17-17-17, Registered Dual in-Line Memory Module (RDIMM) A -N/A- COMPLY_5012
Miscellaneous Parts
Airflow Guide
777302-001 Airflow baffle - Plastic baffle that mounts behind the fan cage on top of the processor heat sinks A -N/A- COMPLY_2912
Other Accessories
Rack Mount Kit
744114-001 Easy install rack mount slide rail kit - For 2U high Small Form Factor (SFF) model servers A -N/A- COMPLY_5012
Power Cords
PDU
142258-001 AC Power Distribution Unit (PDU) power cord (Black) - 250 V ac, 16 AWG, 2.0 m (6.6 ft) long - Includes IEC-320 C14 (M) connector to IEC 320 C13 (F) connector A -N/A- COMPLY_2706
142258-002 AC Power Distribution Unit (PDU) power cord (Black) - 250 V ac, 16 AWG, 2.5 m (8.2 ft) long - Includes IEC-320 C14 (M) connector to IEC 320 C13 (F) connector A -N/A- COMPLY_5012
416151-B21 Power Distribution Unit (PDU) power cord -N/A- -N/A- COMPLY_2706
Power Cord Please click here for important information regarding the differences between Power Cords, Power Modules, and AC Adapters.
142258-006 Power Distribution Unit (PDU) power cord (Black) - IEC 320 C14 (M) connector to IEC 320 C13 (F) connector - 1.37 m (4.5 ft) long - 250 V, 16 A A -N/A- COMPLY_2706
142263-003 Power cord OPT-905 - 3-wire, 3.0 m (9.8 ft) long N -N/A- COMPLY_2706
142263-008 Power cord .7m (2.39ft) - C13 receptacle -N/A- -N/A- COMPLY_2706
142766-005 AC power cord A -N/A- COMPLY_5012
188493-002 250V AC power cord - 3.7m (12ft) long, 15A, C13-NEMA6-15P A -N/A- COMPLY_1906
416151-001 Power Cord - 1.82 m (6 ft) long, C13 -N/A- -N/A- COMPLY_2706
491683-AA1 AC power 3-wire, 1.83 m (6 ft) long cord black A -N/A- COMPLY_2706
538266-001 Power cord (black) - Three conductor, 1.82 m (6 ft) long - Has straight (F) C13 receptacle (For 100 V in Japan) A -N/A- COMPLY_2706
Power Module Parts
Adapter
669279-001 Ethernet 10Gb 2-port 560SFP+ adapter - Has two 10Gbe SFP+ ports and 256MB integrated memory - Provides up to 40Gb/sec bi-directional per adapter - Requires one x8 PCI (Gen 2) Express slot (backward compatible with x4 PCI Express) ; B -N/A- COMPLY_2912
669281-001 Ethernet 10Gb 2-port 560FLR-SFP+ adapter, FlexibleLOM form-factor - Has two 10Gbe SFP+ ports and 128MB integrated memory - Provide up to 40Gb bi-directional per adapter - Requires one x8 PCI (Gen 2) Express slot B -N/A- COMPLY_2912
701525-001 Ethernet 10Gb 2-port 561FLR-T adapter, FlexibleLOM form factor - Has two 10Gbps RJ45 ports featuring the 10Gb Intel X540 Controller - Requires one x8 PCI (Gen 2) FlexibleLOM slot - Requires CAT6 UTP or better twisted-pair B -N/A- COMPLY_2912
717708-002 Ethernet 10Gb 2-port 561T adapter - Has two 10G BASE-T RJ45 ports and has Intel X540 processor - Requires one x8 (Gen2) PCI Express slot - Requires CAT6A UTP or better twisted-pair B -N/A- COMPLY_2912
789897-001 Ethernet 1Gb 4-port 331FLR adapter, FlexibleLOM form-factor - Has four 10/100/1000BASE-T RJ45 ports and 276MB integrated memory - Requires one x4 PCI (Gen 2) FlexibleLOM slot (mechanically compatible with x8 and x16 PCI FlexibleLOM slots) N -N/A- COMPLY_5012
Power Supply Parts
Power Supply
754377-001 500W Flex Slot Platinum hot-plug power supply - Installs in computer chassis as primary or redundant supply (94% efficiency) - Requires 100-240VAC at 50/60Hz - Multiple power supplies used in the sever must be the same model number ; A -N/A- COMPLY_2706
754378-001 800W Flex Slot Titanium hot-plug power supply - Installs in computer chassis as primary or redundant supply (96% efficiency) - Requires 200-240VAC at 50/60Hz - Multiple power supplies used in the sever must be the same model number A -N/A- COMPLY_2706
754379-001 800W Flex Slot Universal hot-plug power supply - Installs in computer chassis as primary or redundant supply (94% efficiency) - Requires 200-277VAC at 50/60Hz or 380VDC - Multiple power supplies used in the sever must be the same model number A -N/A- COMPLY_1606
754381-001 800 Watt Flex Slot Platinum hot-plug power supply - Installs in computer chassis as primary or redundant supply (94% efficiency) - Requires 100 - 240 V ac at 50/60 Hz - Multiple power supplies used in the sever must be the same model number ; A -N/A- COMPLY_2706
754382-001 800W Flex Slot hot-plug DC power supply - Installs in computer chassis as primary or redundant supply (92% efficiency) - Requires -48 VDC nominal input voltage - Multiple power supplies used in the sever must be the same model number ; A -N/A- COMPLY_2912
754383-001 1400W Flex Slot Platinum Plus hot-plug power supply - Installs in computer chassis as primary or redundant supply (94% efficiency) - Requires 200-240VAC at 50/60Hz - Multiple power supplies used in the sever must be the same model number A -N/A- COMPLY_2706
Processors
Heat Sink
777290-001 Standard efficiency heatsink assembly - For use with processors less than or equal to 105W A -N/A- COMPLY_5012
Processor
835601-001 Intel Xeon E5-2620 v4 Eight-Core 64-bit processor - 2.1GHz base frequency (Broadwell, 20MB Intel Smart Cache, Intel QuickPath Interconnect (QPI) speed 8.0 GT/s, 85W Thermal Design Power (TDP), FCLGA 2011-3 socket) ; C -N/A- COMPLY_5012
835602-001 Intel Xeon E5-2630 v4 Ten-Core 64-bit processor - 2.2GHz base frequency (Broadwell, 25MB Intel Smart Cache, Intel QuickPath Interconnect (QPI) speed 8.0 GT/s, 85W Thermal Design Power (TDP), FCLGA 2011-3 socket) C -N/A- COMPLY_5012
835603-001 Intel Xeon E5-2640 v4 Ten-Core 64-bit processor - 2.4GHz base frequency (Broadwell, 25MB Intel Smart Cache, Intel QuickPath Interconnect (QPI) speed 8.0 GT/s, 90W Thermal Design Power (TDP), FCLGA 2011-3 socket) C -N/A- COMPLY_5012
835604-001 Intel Xeon E5-2650 v4 Twelve-Core 64-bit processor - 2.2GHz base frequency (Broadwell, 30MB Intel Smart Cache, Intel QuickPath Interconnect (QPI) speed 9.6 GT/s, 105W Thermal Design Power (TDP), FCLGA 2011-3 socket) C -N/A- COMPLY_5012
835605-001 Intel Xeon E5-2660 v4 Fourteen-Core 64-bit processor - 2.0GHz base frequency (Broadwell, 35MB Intel Smart Cache, Intel QuickPath Interconnect (QPI) speed 9.6 GT/s, 105W Thermal Design Power (TDP), FCLGA 2011-3 socket) C -N/A- COMPLY_5012
835606-001 Intel Xeon E5-2680 v4 Fourteen-Core 64-bit processor - 2.4 GHz base frequency (Broadwell), 35MB Intel Smart Cache, Intel QuickPath Interconnect (QPI) speed 9.6 GT/s, 120 W Thermal Design Power (TDP), FCLGA 2011-3 socket C -N/A- COMPLY_5012
835607-001 Intel Xeon E5-2690 v4 Fourteen-Core 64-bit processor - 2.6GHz base frequency (Broadwell, 35MB Intel Smart Cache, Intel QuickPath Interconnect (QPI) speed 9.6 GT/s, 135W Thermal Design Power (TDP), FCLGA 2011-3 socket) C -N/A- COMPLY_5012
835608-001 Intel Xeon E5-2630L v4 Ten-Core 64-bit low-power processor - 1.8GHz base frequency (Broadwell, 25MB Intel Smart Cache, Intel QuickPath Interconnect (QPI) speed 8.0 GT/s, 55W Thermal Design Power (TDP), FCLGA 2011-3 socket) ; C -N/A- COMPLY_5012
835609-001 Intel Xeon E5-2650L v4 Fourteen-Core 64-bit low-power processor - 1.7GHz base frequency (Broadwell, 35MB Intel Smart Cache, Intel QuickPath Interconnect (QPI) speed 9.6 GT/s, 65W Thermal Design Power (TDP), FCLGA 2011-3 socket) C -N/A- COMPLY_5012
835612-001 Intel Xeon E5-2643 v4 Six-Core 64-bit processor - 3.4GHz base frequency (Broadwell), 20MB Intel Smart Cache, Intel QuickPath Interconnect (QPI) speed 9.6 GT/s, 135W Thermal Design Power (TDP), FCLGA 2011-3 socket ; C -N/A- COMPLY_5012
835613-001 Intel Xeon E5-2667 v4 Eight-Core 64-bit processor - 3.2GHz base frequency (Broadwell, 25MB Intel Smart Cache, Intel QuickPath Interconnect (QPI) speed 9.6 GT/s, 135W Thermal Design Power (TDP), FCLGA 2011-3 socket) C -N/A- COMPLY_5012
835614-001 Intel Xeon E5-2683 v4 Sixteen-Core 64-bit processor - 2.1GHz base frequency (Broadwell, 40MB Intel Smart Cache, Intel QuickPath Interconnect (QPI) speed 9.6 GT/s, 120W Thermal Design Power (TDP), FCLGA 2011-3 socket) C -N/A- COMPLY_5012
835615-001 Intel Xeon E5-2695 v4 Eighteen-Core 64-bit processor - 2.1GHz base frequency (Broadwell, 45MB Intel Smart Cache, Intel QuickPath Interconnect (QPI) speed 9.6 GT/s, 120W Thermal Design Power (TDP), FCLGA 2011-3 socket) C -N/A- COMPLY_5012
835616-001 Intel Xeon E5-2697 v4 Eighteen-Core 64-bit processor - 2.3 GHz base frequency (Broadwell, 45MB Intel Smart Cache, Intel QuickPath Interconnect (QPI) speed 9.6 GT/s, 145 W Thermal Design Power (TDP), FCLGA 2011-3 socket) C -N/A- COMPLY_5012
835617-001 Intel Xeon E5-2698 v4 Twenty-Core 64-bit processor - 2.2GHz base frequency (Broadwell, 50MB Intel Smart Cache, Intel QuickPath Interconnect (QPI) speed 9.6 GT/s, 135W Thermal Design Power (TDP), FCLGA 2011-3 socket) C -N/A- COMPLY_5012
835618-001 Intel Xeon E5-2699 v4 Twenty-two-Core 64-bit processor - 2.2 GHz base frequency (Broadwell, 55MB Intel Smart Cache, Intel QuickPath Interconnect (QPI) speed 9.6 GT/s, 145W Thermal Design Power (TDP), FCLGA 2011-3 socket) C -N/A- COMPLY_5012
841034-001 Intel Xeon E5-2687W v4 Twelve-Core 64-bit processor - 3.0GHz base frequency (Broadwell, 30MB Intel Smart Cache, Intel QuickPath Interconnect (QPI) speed 9.6 GT/s, 160W Thermal Design Power (TDP), FCLGA 2011-3 socket) C -N/A- COMPLY_5012
841035-001 Intel Xeon E5-2697A v4 Sixteen-Core 64-bit processor - 2.6GHz base frequency (Broadwell, 40MB Intel Smart Cache, Intel QuickPath Interconnect (QPI) speed 9.6 GT/s, 145W Thermal Design Power (TDP), FCLGA 2011-3 socket) C -N/A- COMPLY_5012
Racks, Rack Accessories
Arm
744116-001 Cable management arm kit - Guides the power and interface cables to prevent binding when the server is slid in and out of the rack - Mounts to the rear of the rack A -N/A- COMPLY_5012
Rack Mount Kit
744114-001 Easy install rack mount slide rail kit - For 2U high Small Form Factor (SFF) model servers A -N/A- COMPLY_5012
Router Parts
Module
777288-001 Optional system insight display (SID) /power switch module assembly - Includes the SID assembly, power switch, UID switch, status LEDs, and USB connector - For use with servers configured with small form factor (SFF) drive bays A -N/A- COMPLY_2706
777289-001 Standard cabled power switch module assembly (no internal system insight display) - Includes the power switch, UID switch, and status LEDs - For use with servers configured with small form factor (SFF) drive bays A -N/A- COMPLY_2912
Switch Module Parts
Switch
410530-001 Server switch 2X1X16, IP console, USB/Virtual Media (VM) A -N/A- COMPLY_2706
System Chassis Parts
Bracket
667263-001 Support bracket with card guides - Supports the rear of the PCIe cards when installed on the system I/O board - Includes left and right support brackets A -N/A- COMPLY_5012
System Electronics Parts
Fan
777285-001 SPS-Fan Module (STD) DL38x Gen9 ; A -N/A- COMPLY_2912
777286-001 High performance fan module - For use on servers configured with 12 large form factor drives, 24 small form factor drives, certain graphics cards, and/or ASHRAE operating environments (Six used) ; A -N/A- COMPLY_2706